subject

For each of the following scenarios, list which instructions would no longer function properly in the single-cycle datapath if the scenario were to occur. When you list instructions, assume instructions are only of the following types: loads, stores, arithmetic, arithmetic with immediates, branches. (a) Which instructions fail to operate correctly if the RegWrite wire is stuck at 1?
(b) Which instructions fail to operate correctly if the ALUSrc wire is stuck at 1?
(c) Which instructions fail to operate correctly if the Reg2Loc wire is stuck at 1?

ansver
Answers: 1

Another question on Computers and Technology

question
Computers and Technology, 21.06.2019 18:00
Which if the following allows you to view and access important information about your documents all in one location
Answers: 3
question
Computers and Technology, 22.06.2019 03:30
Write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removedproblems 1.1 write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removed 20 power system relaying from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0+j0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the stub-end fault Γ­β€’ figure 1.16 problem 1.1 system data for figure 1.16 from to positive sequence 0.0+j0.1 0.05j0.15 0.04 j0.2 0.01 jo.i 0.015 + j0.15 0.01 j0.19 0.01 +j0.19 0.03+j0.1 0.0+j0.08 6 6 6 from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0 + j 0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b1, and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the Ò€śstub-endÒ€Ε₯ fault.
Answers: 2
question
Computers and Technology, 22.06.2019 15:30
When creating a budget, log fixed expenses before income. after income. after savings. at the top.
Answers: 1
question
Computers and Technology, 22.06.2019 18:00
Which of the following physical laws can make the flow of water seem more realistic? a. motion b. gravity c. fluid dynamics d. thermodynamics
Answers: 2
You know the right answer?
For each of the following scenarios, list which instructions would no longer function properly in th...
Questions
question
Mathematics, 13.10.2019 10:10
question
History, 13.10.2019 10:10
Questions on the website: 13722360