subject
Physics, 04.04.2021 02:10 bapefer498

For ionization detector, if we use gas as the sensitive medium, we can use it in two formats: sealed (left figure) and vented (right figure). In radiation clinic, we typically use the sealed ionization chamber to monitor the fluence of the x-ray beams in the linac head, while we use vented ion
chamber to check the delivered dose accuracy inside a phantom (for patient QA). Based on the
working principle of ionization chamber, discuss
a. When using the vented ion chamber, do we need to know the local atmosphere pressure and
temperature for a proper performance calibration? Why?
b. From the maintenance, measurement accuracy, etc., discuss the advantage and disadvantage of
using a sealed and vented ion chamber.

2. Discuss about the advantage and disadvantage of the cyclotron, synchrotron and linac in the aspects
of accelerator size, beam energy limitation, maintenance, beam intensity, etc.

Serious answers only please, I will flag your answer if you are just trying to gain points without trying.


For ionization detector, if we use gas as the sensitive medium, we can use it in two formats: seale

ansver
Answers: 2

Another question on Physics

question
Physics, 22.06.2019 13:00
What causes the formation of ocean currents?
Answers: 1
question
Physics, 22.06.2019 16:20
Iupil u5l aluve time remaining 01: 53: 45 ei and both agreed that childhood experiences play an important role in the development of oneself a sigmund freud alfred adler b. carl jung alfred adler c.carl jung erik erikson d. sigmund freud.. carl jung select the best answer from the choices provided save and exit next submit mark this and return
Answers: 1
question
Physics, 22.06.2019 20:50
Asquare 1m x 1m plate is shown below. all four of its edges are kept at 0 co. at t=0the temperature distribution is given by: y xtsins n75)=.a) using separation of variables determine the temperature distribution t(x,y,t)along the plate at any time t.b) discretize the heat conduction equation +=22222 txtusing a second-order centered difference scheme for the two second derivatives and a first-order forward euler scheme for the first derivative. using von neumann stability analysis, determine the stability criterion for the proposed discretization scheme in terms of , hand t. solve for the maximum allowable time step tmax
Answers: 1
question
Physics, 23.06.2019 03:00
There are 3 ways heat can be transferred: through solids, called , through liquids and gases , called , and through electromagnetic waves, called
Answers: 1
You know the right answer?
For ionization detector, if we use gas as the sensitive medium, we can use it in two formats: sealed...
Questions
question
Mathematics, 02.10.2019 23:50
Questions on the website: 13722367