Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 19:20
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10°c. the air leaves the coil at 15°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c...
Questions
question
Mathematics, 22.05.2020 05:57
question
Mathematics, 22.05.2020 05:57
question
Mathematics, 22.05.2020 05:57
question
Mathematics, 22.05.2020 05:57
question
History, 22.05.2020 05:57
Questions on the website: 13722361