subject
Engineering, 11.07.2019 01:30 acsmelis

Anew underground pipeline at a chemical complex is to be placed parallel to an existing underground pipeline. the existing line has an od of 8.9 cm, carries a fluid at 283 k and is not insulated. the new line will have an od of 11.4 cm and will carry a fluid at 335 k. the center-to-center distance between the two pipelines will be 0.76 m. the ground at the plant site has an average thermal conductivity of 0.7 w/m k. in order to determine whether the new line will need to be insulated, calculate the rate of heat transfer between the two pipelines per meter of pipe length if the new line is not insulated. for the purpose of this calculation, neglect the resistances of the pipe walls and the convective resistances between the fluids and pipe walls.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
You are making beer. the first step is filling the glass carboy with the liquid wort. the internal diameter of the carboy is 15 in., and you wish to fill it up to a depth of 2 ft. if your wort is drawn from the kettle using a siphon process that flows at 3 gpm, how long will it take to fill?
Answers: 1
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
You know the right answer?
Anew underground pipeline at a chemical complex is to be placed parallel to an existing underground...
Questions
question
Social Studies, 22.12.2021 23:00
Questions on the website: 13722359