subject
Engineering, 21.08.2019 03:10 oceaneyez

Aheat pump is used to warm a building in the winter. this system implements an ideal vapor-compression cycle with r-134a as the working fluid. the cycle operates between 140 kpa and 900 kpa, with a mass flow rate of 0.03 kg/s. determine: (a) the heating load that can be met kw. (b) the power input required for this system kw (c) the coefficient of performance (d) the warmest outside temperature at which this particular cycle is unable to operate ∘c

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Aheat pump is used to warm a building in the winter. this system implements an ideal vapor-compressi...
Questions
question
Biology, 13.03.2020 07:11
question
English, 13.03.2020 07:12
question
Mathematics, 13.03.2020 07:13
question
Geography, 13.03.2020 07:13
question
Mathematics, 13.03.2020 07:14
question
Mathematics, 13.03.2020 07:14
Questions on the website: 13722362