subject
Engineering, 21.08.2019 05:20 helpplz84

Tests on an axial compressor revealed that the relative mach number at thee rotor inlet as 0.7 when the flow coefficient was 0.5. the flow angle exiting the rotor is 300 from the axial direction and the velocity triangles are symmetric at the blade mean radius. if the inlet stagnation temperature is 289 k, determine the stagnation temperature rise obtained under the above conditions

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i.d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
question
Engineering, 06.07.2019 03:30
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
You know the right answer?
Tests on an axial compressor revealed that the relative mach number at thee rotor inlet as 0.7 when...
Questions
question
Physics, 08.12.2021 19:40
question
Mathematics, 08.12.2021 19:40
question
Social Studies, 08.12.2021 19:40
question
Mathematics, 08.12.2021 19:40
question
Spanish, 08.12.2021 19:40
Questions on the website: 13722361