subject
Engineering, 23.08.2019 01:30 mirandac9394

Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105kpa (gauge) and a condensing pressure of 920 kpa (gauge). there is a sub-cooling of 3k with a superheat of the gas entering the compressor of 8k. the compressor is a four-cylinder reciprocating compressor with a bore of 67mm and a stroke of 57mm with an estimated capacity of 35kw. the compressor is directly coupled to an electric motor running at 1470rev/min and a power consumption of 19,5 kw. calculate: 1. the clearance volume efficiency if the compressor clearance is 3,6% 2. the actual volumetric efficiency 3. the compression efficiency when the mechanical efficiency is 85% and the motor efficiency 90%.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
The mass flow rate of the fluid remains constant in all steady flow process. a)- true b)- false
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105kpa (...
Questions
question
English, 06.08.2021 14:00
question
English, 06.08.2021 14:00
question
History, 06.08.2021 14:00
question
Mathematics, 06.08.2021 14:00
question
Mathematics, 06.08.2021 14:00
question
Mathematics, 06.08.2021 14:00
Questions on the website: 13722359