subject
Engineering, 24.08.2019 05:10 adelawilliams60

The maintenance manager of your facility has asked you to evaluate a particular welding booth that utilizes a local exhaust ventilation (lev) system to remove the contaminant at the source. the exhaust system does not appear to be drawing enough of the welding fumes away from the employees to reduce the iron oxide below the permissible exposure limit (pel) of 10 mg/m3. during your investigation, you determine that the diameter of the duct system is 8 inches and has an air velocity of 350 fpm (feet per minute). the welding operation is performed at a distance of 1.5 feet from the exhaust opening. determine the flow rate, and provide your recommendations on the control measures that could improve the capture of the iron oxide contaminant.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
question
Engineering, 04.07.2019 18:10
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
question
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60Β°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
The maintenance manager of your facility has asked you to evaluate a particular welding booth that u...
Questions
question
Mathematics, 01.03.2021 18:50
question
Geography, 01.03.2021 18:50
question
Mathematics, 01.03.2021 18:50
Questions on the website: 13722361