Atank contains liquid nitrogen at -190℃ is suspended in a vacuum shell by three stainless steel rods 0.80 cm in diameter and 3 meters long with a thermal conductivity of 16.3 w/m^2-℃. if the ambient air outside the vacuum shell is 15℃, calculate the magnitude of the conductive heat flow in watts along the support rods. a. 0.168 b. 0.0587 c. 0.182 d. 0.176

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
You know the right answer?
Atank contains liquid nitrogen at -190℃ is suspended in a vacuum shell by three stainless steel rods...
Questions
question
Mathematics, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
History, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
Mathematics, 30.04.2021 23:00
question
Biology, 30.04.2021 23:00
Questions on the website: 13722367