Engineering, 02.09.2019 16:30 ineedhelp368
Amixture of 1 kmol of hydrogen (h2) and n kmol of oxygen (o2), initially at 25°c and 1 atm, burns completely in a closed, rigid, insulated container. the container finally holds a mixture of water vapor and o2 at 2000 k. the ideal gas model applies to each mixture and there is no change in kinetic or potential energy between the initial and final states. determine: (a) the value of n. (b) the final pressure, in atm.
Answers: 3
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
Engineering, 04.07.2019 18:10
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
Amixture of 1 kmol of hydrogen (h2) and n kmol of oxygen (o2), initially at 25°c and 1 atm, burns co...
Biology, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
Social Studies, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
Chemistry, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
Biology, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13
English, 19.05.2020 16:13
Mathematics, 19.05.2020 16:13