Calculate the distance to be laid out using the following
data:
tape length - 100.015 f...
Engineering, 13.09.2019 16:30 Darkwynd11791
Calculate the distance to be laid out using the following
data:
tape length - 100.015 ft.
slope - zenith 87 degrees 15' minutes
temperature - 64 degrees fahrenheit
required horizontal distance - 400ft.
Answers: 2
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
History, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
English, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
History, 17.09.2020 08:01
English, 17.09.2020 08:01
Social Studies, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Mathematics, 17.09.2020 08:01
Spanish, 17.09.2020 08:01