Question#4 a 100-kva 8000/277-v distribution transformer has the following resistances and reactances:
rp = 5 ohm
rs = 5 miliohm
xp = 6 ohm
xs = 6 miliohm
rc = 50 kilo ohm
xm = 10 kilo ohm
the excitation branch impedances are given referred to the high-voltage side of the transformer.
(a) find the equivalent circuit of this transformer referred to the low-voltage side.
(b) find the per-unit equivalent circuit of this transformer.
(c) assume that this transformer is supplying rated load at 277 v a

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
You know the right answer?
Question#4 a 100-kva 8000/277-v distribution transformer has the following resistances and reactance...
Questions
question
Mathematics, 07.09.2020 14:01
question
Spanish, 07.09.2020 14:01
question
Mathematics, 07.09.2020 14:01
question
Medicine, 07.09.2020 14:01
question
Mathematics, 07.09.2020 14:01
Questions on the website: 13722359