Engineering, 01.10.2019 22:00 Pookiev

Arigid, insulated tank that is initially evacuated is connected through a valve to a supply line that carries steam at 4 mpa. now the valve is opened, and steam is allowed to flow into the tank until the pressure reaches 4 mpa, at which point the valve is closed. if the final temperature of the steam in the tank is 550°c, determine the temperature of the steam in the supply line and the flow work per unit mass of the steam.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 06.07.2019 03:30
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
You know the right answer?
Arigid, insulated tank that is initially evacuated is connected through a valve to a supply line tha...
Questions
question
Social Studies, 03.12.2021 02:30
question
Social Studies, 03.12.2021 02:30
question
Mathematics, 03.12.2021 02:30
question
Biology, 03.12.2021 02:30
question
Mathematics, 03.12.2021 02:30
Questions on the website: 13722359