You come across a large boiler with the following characteristics: steam pressure 145 psig measured fuel firing rate: 21 mmbtu/hr (fuel) and steady near high fire stack oxygen: 7% stack temperature: 510°f boiler air inlet temp 80°f deaerator temp/pressure: 225°f/5 psig make-up water temp make-up water flow feedwater conductivity boiler conductivity 70°f 350 gallons/hr (before energy recovery in #11) 185 umhos/cm 3,200 umhos/cm natural gas fuel cost: $5.00/mmbtu find: 1. compute the stack loss efficiency for the boiler 2. are the stack temperature and oxygen reasonable for these operating conditions? explain your answer 3. what oxygen and stack temperature would you recommend if not? what is the efficiency with your chosen values? 4. if the stack temperature increased to 610°f, estimate the stack loss efficiency using the rule of thumb approach. 5. find the steam production rate, based on stack loss efficiency you found in #1. 6. find the boiler size in boiler hp. 7. if the boiler operates at this condition 6,000 hrs/yr. (24 hrs/day 5 days/wk), find the annual fuel cost. 8. compute the blow down rate for the boiler and the blowdown flow in lb/hr 9. find the blowdown loss as a percent of the fuel fired, based on the make-up water temperature. 10. what does the blowdown cost the facility in natural gas cost per year? 11. if we were to flash the blowdown to 5 psig and use in the da, find the steam savings, the annual fuel savings, and annual cost savings. 12. estimate the steam condensate return rate. is it reasonable?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 19:10
Asteam is contained in a rigid tank with a volume of 1 m3. initially, the pressure and temperature are 7 bar and 500 oc, respectively. the temperature drops due to cooling process. determine: (1) the temperature at which condensation begins in °c, (2) the fraction of the total mass that has condensed when the pressure decreased to 0.5 bar. (3) the volume in m3 occupied by saturated liquid at the final state?
Answers: 3
question
Engineering, 04.07.2019 19:10
The air in an automobile tire with a volume of 0.015 m3 is at 32°c and 140 kpa gage. determine the amount of air that must be added to raise the pressure to the recommended value of 206 kpa gage. assume the atmospheric pressure to be 128 kpa and the temperature and the volume to remain constant.[r-0.287 kj/kgk]
Answers: 3