subject
Engineering, 29.10.2019 06:31 alicia234

A500mva, 220kv/24kv, three phase y-δ transformer has an equivalent series impedance of 1 + j5 ω per phase referred to the high-voltage side. the transformer is supplying a three phase load of 500mva, 0.85 power factor lagging at a terminal voltage of 24 kv (line to line) on its low-voltage side. the primary is supplied from a feeder with an impedance of 0.5+ j1 ω per phase. determine the line-neutral voltage in kv across the load when it is referred to the transformer high side voltage.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
You know the right answer?
A500mva, 220kv/24kv, three phase y-δ transformer has an equivalent series impedance of 1 + j5 ω per...
Questions
question
Mathematics, 26.10.2020 17:00
Questions on the website: 13722361