subject
Engineering, 30.10.2019 06:31 diane8879

Clearly show and label the following process lines and state-points on a psychrometric chart. (a)outdoor air at 35f dry-bulb temperature and 100 percent relative humidity is heated in a furnace to 100f dry-bulb temperature (b)saturated steam at 200f is then sprayed into the air to increase its relative humidity to 40 percent. (c)the air is then supplied to a space with a condition line having a sensible-heat ratio of 0.7, and the air exits the space at a dry-bulb temperature of 70f.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:10
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
Clearly show and label the following process lines and state-points on a psychrometric chart. (a)out...
Questions
question
Physics, 17.06.2021 09:10
question
Mathematics, 17.06.2021 09:10
question
Mathematics, 17.06.2021 09:10
question
Mathematics, 17.06.2021 09:10
question
English, 17.06.2021 09:10
Questions on the website: 13722359