subject
Engineering, 10.11.2019 06:31 AreYouMyNewDad

Ninety-five percent of the acetone vapor in an 85 vol.% air stream is to be absorbed by countercurrent contact with pure water in a valve-tray column with an expected overall tray efficiency of 50 %. the column will operate essentially at 20 ΒΊc and 101 kpa pressure. equilibrium data for acetone-water at these conditions are: mole percent acetone in water 3.30 7.20 11.7 17.1 acetone partial pressure in air, torr 30.00 62.80 85.4 103.0 calculate:
(a) the minimum value of s/g, the ratio of moles of water per mole of air.
(b) the number of equilibrium stages required using a value of s/g of 1.25 times the minimum. ( indicate operating line obviously)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:10
Slip occurs via two partial dislocations because of (a) the shorter path of the partial dislocation lines; (b) the lower energy state through partial dislocations; (c) the charge balance.
Answers: 1
question
Engineering, 04.07.2019 18:10
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Ninety-five percent of the acetone vapor in an 85 vol.% air stream is to be absorbed by countercurre...
Questions
question
Mathematics, 05.11.2020 02:40
question
Spanish, 05.11.2020 02:40
question
Biology, 05.11.2020 02:40
question
Mathematics, 05.11.2020 02:40
question
Mathematics, 05.11.2020 02:40
question
Mathematics, 05.11.2020 02:40
question
SAT, 05.11.2020 02:40
Questions on the website: 13722367