Engineering, 13.11.2019 03:31 kellypechacekoyc1b3
Oil at 15°c is to be heated by saturated steam at 1 atm in a double-pipe heat exchanger to a temperature of 25°c. the inner and outer diameters of the annular space are 3 cm and 5 cm, respectively, and oil enters with a mean velocity of 0.8 m/s. the inner tube may be assumed to be isothermal at 100°c, and the outer tube is well insulated. assuming fully developed flow for oil, determine the tube length required to heat the oil to the indicated temperature. in reality, will you need a shorter or longer tube? explain.
Answers: 3
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
Engineering, 04.07.2019 18:20
For each of the following process: a) sketch the p-v diagram, b)sketch t-s diagram, c) sketch t-v diagram, d) sketch the boundary work on one of the diagrams (a, b or c) and e) sketch the reversible heat transfer on one of the diagrams (a, b or c): 1- isobaric process from compressed liquid to superheated vapor 2- isothermal process from compressed liquid to superheated vapor 3- isentropic process from compressed liquid to superheated vapor
Answers: 3
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
Oil at 15°c is to be heated by saturated steam at 1 atm in a double-pipe heat exchanger to a tempera...
Engineering, 30.10.2020 14:00
English, 30.10.2020 14:00
Mathematics, 30.10.2020 14:00
Mathematics, 30.10.2020 14:00
History, 30.10.2020 14:00
Mathematics, 30.10.2020 14:00
Mathematics, 30.10.2020 14:00
Biology, 30.10.2020 14:00
World Languages, 30.10.2020 14:00
Social Studies, 30.10.2020 14:00
Chemistry, 30.10.2020 14:00