subject
Engineering, 22.11.2019 04:31 tot92

Afield test is conducted in an unconfined aquifer by pumping 1,300 ft3 /hr from an 8-inch-diameter well penetrating the aquifer. the undisturbed aquifer thickness is 46 ft. the drawdowns, measured at steady state at various locations, are tabulated below along with the associated semi-log plot of h2 vs. log r. determine the coefficient of permeability and how far away from the well you must be before the drawdown becomes less than 2.5 ft. r (ft) 0.33 40 125 350 s (ft) 6.05 4.05 3.57 3.05

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
You know the right answer?
Afield test is conducted in an unconfined aquifer by pumping 1,300 ft3 /hr from an 8-inch-diameter w...
Questions
question
Computers and Technology, 14.04.2021 08:10
question
Mathematics, 14.04.2021 08:10
question
Mathematics, 14.04.2021 08:10
question
Mathematics, 14.04.2021 08:10
question
Chemistry, 14.04.2021 08:10
question
Mathematics, 14.04.2021 08:10
Questions on the website: 13722359