subject
Engineering, 27.11.2019 20:31 nananna90

Pprotocol uses 1’s complement for ip header checksums. suppose you have the following three 16-bit words: 0101011001100011, 11100011110, 0111001010101100. what is the 1’s complement of the sum of these 16-bit words? show all work step by step in the worksheet given below. note: first find sum of first two words, then find sum of that and the 3rd word, then find its 1’s complement. why is it that ip takes the 1’s complement of the sum; that is, why not just use the sum? (2 points) with the 1’s complement scheme, how does the receiver detect errors? (4 points) is it possible that a 1-bit error (one bit is flipped) will go undetected? if yes, give an example. (4 points) how about a 2-bit error? if yes, give an example. (4 points)

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
question
Engineering, 04.07.2019 18:20
Amixture of slurry and mud is to be pumped through a horizontal pipe of diameter 500 mm. the fluid behaves as a bingham plastic with a yield stress of 30 pa and viscosity 0.04 pa.s. describe the effects of the shear stress through a transverse section of the pipe by plotting the variation in shear stress and velocity profile: (i) just before the slurry starts to move (ii) as the slurry flows when the pressure gradient is double that in part (i)
Answers: 3
question
Engineering, 06.07.2019 04:10
Natural gas (95 percent methane and 5 percent ethane by volume) flows through a 90 cm diameter pipeline with a velocity of 3 m/s. the pressure in the pipeline is 700 kpa, and the temperature is 15°c. calculate: (a) the mass and volumetric flow rates in this pipe.
Answers: 1
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10°c. the air leaves the coil at 15°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
Pprotocol uses 1’s complement for ip header checksums. suppose you have the following three 16-bit w...
Questions
question
Mathematics, 27.01.2021 17:40
question
Geography, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
question
English, 27.01.2021 17:40
question
Mathematics, 27.01.2021 17:40
Questions on the website: 13722360