subject
Engineering, 30.11.2019 02:31 topangabraith

Create two threads t1 and t2. t1 and t2 share an integer data counter. the job of t1 is to increase the value of counter by 1 when t1 is scheduled. the job of t2 is to decrease the value of counter by 1 when t2 is scheduled. because counter is a critical section, you need to use semaphore to implement mutual exclusion between t1 and t2. here is the api you may use: sem_init: initialize an unnamed semaphore sem_wait: lock a semaphore, which is equivalent to the p operation. sem_post: unlock a semaphore, which is equivalent to the v operation. sem_destroy: destroy an unnamed semaphore. here is the basic structure of the program: int counter; //shared between t1 and t2

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
question
Engineering, 04.07.2019 18:20
Asimple rankine cycle uses water as the working fluid. the water enters the turbine at 10 mpa and 480c while the condenser operates at 6 kpa. if the turbine has an isentropic efficiency of 80 percent while the pump has an isentropic efficiency of 70 percent determine the thermal efficiency
Answers: 1
question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
question
Engineering, 04.07.2019 19:10
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces.a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
You know the right answer?
Create two threads t1 and t2. t1 and t2 share an integer data counter. the job of t1 is to increase...
Questions
question
Mathematics, 19.05.2020 02:06
question
English, 19.05.2020 02:06
question
History, 19.05.2020 02:06
Questions on the website: 13722363