Asignal m1(t) is band-limited to 3.6khz, and three other signals – m2(t), m3(t) and m4(t) are band-limited to 1.2khz each. these signals are to be transmitted by means of time division multiplexing. the scheme below shows how the multiplexing requirement may be accomplished.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 06.07.2019 04:10
Aheat pump using refrigerant-134a heats a house by using underground water at 8°c as the heat source. the house is losing heat at a rate of 60,000 kj/h. the refrigerant enters the compressor at 280 kpa and 0°c, and it leaves at 1 mpa and 60°c. the refrigerant exits the condenser at 30°c. determine: (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump
Answers: 2
You know the right answer?
Asignal m1(t) is band-limited to 3.6khz, and three other signals – m2(t), m3(t) and m4(t) are band-l...
Questions
question
Mathematics, 06.10.2021 17:20
question
Mathematics, 06.10.2021 17:20
question
Biology, 06.10.2021 17:20
question
English, 06.10.2021 17:20
question
English, 06.10.2021 17:20
Questions on the website: 13722367