subject
Engineering, 13.12.2019 04:31 yuki430

Aheat exchanger consists of a bank of 1200 copper tubes (no fins) with hot air in cross-flow over the tubes and with cold water flowing inside the tubes. the tubes are arranged in-line, with 40 longitudinal rows (along the direction of airflow) and 30 transverse rows. the tubes are 0.0175-m inside diameter and 4-m long, with longitudinal and transverse pitches of 0.07 m. the outside tube diameter is 0.0185 m. the hot air enters the heat exchanger at 600 k and atmospheric pressure, and the cold water enters the heat exchanger at 300 k.

(a) sketch and label a schematic of the heat exchanger; reference this schematic as needed to explain calculation procedures. determine the exit temperatures of both the hot and cold air streams if the flow rate for the hot air stream is 30 kg/s and the flow rate of the cold stream is 15 kg/s. for ease of comparison, evaluate the hot fluid properties at 513 k and the cold fluid properties at 313 k.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 19:10
Asteam is contained in a rigid tank with a volume of 1 m3. initially, the pressure and temperature are 7 bar and 500 oc, respectively. the temperature drops due to cooling process. determine: (1) the temperature at which condensation begins in °c, (2) the fraction of the total mass that has condensed when the pressure decreased to 0.5 bar. (3) the volume in m3 occupied by saturated liquid at the final state?
Answers: 3
question
Engineering, 04.07.2019 19:10
A)-explain briefly the importance of standards in engineering design. b)- what is patent? c)-explain the relationship between these standards: b.s. and b.s.en d)- in engineering design concepts, types of loads and how they act are important factors. explain.
Answers: 3
You know the right answer?
Aheat exchanger consists of a bank of 1200 copper tubes (no fins) with hot air in cross-flow over th...
Questions
question
English, 29.10.2020 17:00
Questions on the website: 13722359