subject
Engineering, 24.12.2019 20:31 keigleyhannah30

Design a filter that meets the specifications below. you need to pick values for any resistors, capacitors or inductors in your circuit. simulate the circuit in pspice to verify that your design meets specifications. use the ideal amplifier component called opamp in your simulations. note, small deviations from the design specifications are allowed and in a real circuit always exist, but they need to be small. show calculations to justify your design (guessing in pspice is not a design solution). (note: this problem has units hz) a. highpass filter with a cutoff frequency of 159mhz

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:10
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200Β°c while the air temperature is 20Β°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200Β°c20Β°c)/2 = 110Β°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10Β°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50Β°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Design a filter that meets the specifications below. you need to pick values for any resistors, capa...
Questions
question
Geography, 27.02.2021 01:00
question
Mathematics, 27.02.2021 01:00
question
Mathematics, 27.02.2021 01:00
question
Chemistry, 27.02.2021 01:00
question
Mathematics, 27.02.2021 01:00
question
Mathematics, 27.02.2021 01:00
Questions on the website: 13722361