To cool a summer home without using a vapor compression refrigeration cycle, air is routed through a plastic pipe (k=0.15 w/m*k, d_inner=0.15m, d_outer=0.17m) that is submerged in an adjoining body of water. the water temperature is nominally at t_infinity=17 degrees celsius and has a convection coefficient of h=1500w/m^2*k is maintained at the outer surface of the pipe. if air from the home enters at t_m, i=29 degrees celsius and a volumetric flow rate of v_i=0.025 m^3/s, what pipe length, l, is needed to provide a discharge temperature of t_m, o=21 degrees celsius?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 18:20
Find the minimum film thickness for a journal bearing with the data below. shaft diameter, d-50 mm, clearance ratio, cdratio? 0.001, shaft speed, n 2000 rpm; bearing length. i 200 mm; eccentricity ration, ? -0.55. ( note, cdratio-ca/d) the minimum film thickness is um
Answers: 2
question
Engineering, 04.07.2019 19:10
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2
You know the right answer?
To cool a summer home without using a vapor compression refrigeration cycle, air is routed through a...
Questions
question
Mathematics, 06.06.2020 08:57
question
Mathematics, 06.06.2020 08:57
question
Mathematics, 06.06.2020 08:57
question
Mathematics, 06.06.2020 08:57
question
Computers and Technology, 06.06.2020 08:57
question
Mathematics, 06.06.2020 08:57
question
English, 06.06.2020 08:57
Questions on the website: 13722360