subject
Engineering, 16.01.2020 04:31 wxvvyyyy

Consider one more time the following contract specification for the static method smooth. smooths a given (@code sequence < integer > }. @param s1 the sequence to smooth @param s2 the resulting sequence @replaces s2 @requires |s1| > = 1 @ensures < pre > |s2| = |s1| - 1 and for all i, j: integer, a, b: string of integer where (s1 = a < i > < j > b) (there exists c, d: string of integer) (|c| = |a| and s2 = c < (i + j)/2 > d)} < /pre > /public static void smooth (sequence < integer > s1, sequence < integer > s2) {. answer the following questions. redesign the method so that it is a function that returns the new (smoothed) sequence instead of replacing a parameter. you need to modify the method header and update the formal contract to reflect the changes. provide two distinct implementations of the newly designed smooth method, one recursive and one iterative (i. e., not using recursion). while you may use method entry, do not use any other method that is introduced in the enhanced interface sequence. among the methods still permitted for your use arc all those inherited by or introduced in sequencekernel, including add, remove, and length.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
You know the right answer?
Consider one more time the following contract specification for the static method smooth. smooths a...
Questions
question
Mathematics, 12.08.2021 22:00
question
Mathematics, 12.08.2021 22:00
Questions on the website: 13722363