subject
Engineering, 17.02.2020 20:11 amakayla57

A stainless steel billet (k = 13 Btu/hr-ft-F, α = 0.24 ft2 /hr), 4 inches in diameter, is passing through a 20 ft. long heat-treating furnace. The initial billet temperature is 200°F, and it must be raised to a minimum temperature of 1500°F before working. The heat transfer coefficient between the furnace gases and the billet surface is 6 Btu/hr ft2 F, and the furnace gases are at 2200°F. At what maximum velocity (ft/min.) can the billet travel through the furnace and satisfy these conditions?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ajournal bearing has a journal diameter of 3.250 in with a unilateral tolerance of 20.003 in. the bushing bore has a diameter of 3.256 in and a unilateral tolerance of 0.004 in. the bushing is 2.8 in long and supports a 700-lbf load. the journal speed is 900 rev/min. find the minimum oil film thickness and the maximum film pressure for both sae 20 and sae 20w-30 lubricants, for the tightest assembly if the operating film temperature is 160°f. a computer code is appropriate for solving this problem.
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
You know the right answer?
A stainless steel billet (k = 13 Btu/hr-ft-F, α = 0.24 ft2 /hr), 4 inches in diameter, is passing th...
Questions
question
Geography, 07.12.2019 08:31
question
Mathematics, 07.12.2019 08:31
Questions on the website: 13722367