subject
Engineering, 18.02.2020 03:28 Anshuman2002

A subsonic diffuser flow is steady and adiabatic with inlet Mach number M1 = 0.6. Total pressure loss in the diffuser is 2% of the inlet total pressure, i. e., pt2/ pt1 = 0.98. The diffuser area ratio is A2/ A1 = 1.50. Assuming that the flow in the diffuser has a uniform exit flow, calculate the exit Mach number M2 the static pressure recovery in the diffuser CPR the (internal) force acting on the diffuser, i. e., Fx, wall, nondimensionalized by the inlet static pressure and area,

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
question
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
You know the right answer?
A subsonic diffuser flow is steady and adiabatic with inlet Mach number M1 = 0.6. Total pressure los...
Questions
question
Mathematics, 18.08.2019 17:50
question
Mathematics, 18.08.2019 17:50
question
Mathematics, 18.08.2019 17:50
question
Social Studies, 18.08.2019 17:50
question
Mathematics, 18.08.2019 17:50
Questions on the website: 13722367