subject
Engineering, 19.02.2020 04:58 jaymariepope3334

Human exposure to radiation is often measured in rems (roentgen-equivalent man), or millirems (mrem). The cancer risk caused by exposure to radiation is through to be approximately 1 fatal cancer per 8,000 person-rems of exposure (eg –1 cancer death if 8,000 people are exposed to 1 rem each, or 10,000 people exposed to 0.8 rems each, etc.).
Natural radioactivity in the environment is thought to expose us to roughly 130 mrem/yr.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ajournal bearing has a journal diameter of 3.250 in with a unilateral tolerance of 20.003 in. the bushing bore has a diameter of 3.256 in and a unilateral tolerance of 0.004 in. the bushing is 2.8 in long and supports a 700-lbf load. the journal speed is 900 rev/min. find the minimum oil film thickness and the maximum film pressure for both sae 20 and sae 20w-30 lubricants, for the tightest assembly if the operating film temperature is 160°f. a computer code is appropriate for solving this problem.
Answers: 3
question
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
Human exposure to radiation is often measured in rems (roentgen-equivalent man), or millirems (mrem)...
Questions
question
Mathematics, 21.06.2021 21:00
question
Mathematics, 21.06.2021 21:00
question
Mathematics, 21.06.2021 21:00
question
Mathematics, 21.06.2021 21:00
Questions on the website: 13722367