subject
Engineering, 24.02.2020 16:44 lerinmarie

5.3 A standard five-day BOD test is run using a mix consisting of four parts distilled water and one part wastewater (no seed). The initial DO of the mix is 9.0 mg / L, and the DO after five days is determined to be 1.0 mg / L. What is BOD(5)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 06.07.2019 05:20
The inner surface of a 0.25m thick brick wall of a furnace is kept at 810ºc, when the outside surrounding air is at 22ºc. the convective heat transfer coefficient of the outer surface is 12 w/m2k and the thermal conductivity of the brick is 0.865 w/mk.neglect the convective resistance for the inner side of the furnace and assume that the problem is steady state and thermal radiation is neglected. (a)-sketch the system and calculate the rate of heat loss per unit wall area. (b)-calculate the temperature of the outer wall surface.
Answers: 2
question
Engineering, 06.07.2019 05:20
An ideal rankine cycle with reheat uses water as the working fluid. the conditions at the inlet to the high pressure turbine are 10mpa, 650°c and the steam is reheated at a constant pressure of 1.4mpa before entering the low pressure turbine. for a condenser pressure of 10kpa, plot the cycle thermal efficiency and quality of steam at the low pressure turbine exit versus reheat temperatures (the temp of steam entering the low pressure turbine) of 400, 500, and 600°c. draw the t-s diagram and show all your work for a reheat temperature of 400°c .note, there will be two plots. one with thermal efficiency on in the ordinate versus reheat temperate and the other will have quality on the ordinate versus reheat temperature. be sure to label all axes with variables and units and include title. the plots must be done on computer.