Engineering, 25.02.2020 17:18 lex3340

The anchor shown is used to tie tower guy cables to the ground and is supported by a distributed force from the soil, which can be approximated as shown. The anchor also is subjected to the loads shown, where P1 = 5 kNand P2 = 3 kN . The anchor is made from aluminum with E = 69 GPa . It is a cylindrical rod with diameter d1 = 4 cm with three segments of length L = 2 m . One end of the rod is linearly tapered to a diameter of d2 = 2 cm.

a. Calculate the intensity of the reaction load, Po
b. Use the reaction found in Part A, po = 13 kN/m , and calculate the total change in length for the anchor.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aflywheel accelerates for 5 seconds at 2 rad/s2 from a speed of 20 rpm. determine the total number of revolutions of the flywheel during the period of its acceleration. a.5.65 b.8.43 c. 723 d.6.86
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
The anchor shown is used to tie tower guy cables to the ground and is supported by a distributed for...
Questions
question
Social Studies, 18.09.2019 09:30
question
Mathematics, 18.09.2019 09:30
question
Computers and Technology, 18.09.2019 09:30
question
Mathematics, 18.09.2019 09:30
question
Mathematics, 18.09.2019 09:30
Questions on the website: 13722360