Engineering, 26.02.2020 05:12 halohero7

An AISI 1030 hot rolled steel bar has a diameter of 1.5in. For unknown factors including the reliability factor, set equal to 1.

Estimate the:

a. Endurance limit (Se’)

b. Corrected endurance limit in bending and rotation (Se). Assume that there is no axial loading. Assume that component is used at room temperature. Assume that a 50% reliability that the endurance strength of your material is within 8% of the mean value reported is acceptable.

c. Corrected endurance limit for reverse bending without rotation (Se). Assume that there is no axial loading. Assume that component is used at room temperature. Assume that a 50% reliability that the endurance strength of your material is within 8% of the mean value reported is acceptable. Note: the size factor will change compared to previous question.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
You know the right answer?
An AISI 1030 hot rolled steel bar has a diameter of 1.5in. For unknown factors including the reliabi...
Questions
question
Mathematics, 20.02.2020 07:22
Questions on the website: 13722361