subject
Engineering, 28.02.2020 04:00 postorivofarms

A Y-connected bank of three identical 100-kVA 9000/300-V2 transformers is supplied with power directly from a large constant-voltage bus. In the short-circuit test, the recorded values on the high-voltage side for one of these transformers are V_SC = 520 I_SC = 10 A P_SC-1 phi = 1100 W (a) If this transformer bank delivers a rated load at 0.88 PF lagging at rated voltage, what is the approximate line-to-line voltage on the primary of the transformer bank? (b) What is the voltage regulation under these conditions? (c) Assume that the primary line voltage of this transformer bank is a constant 520 V, and use Matlab to plot the secondary line voltage as a function of load current for currents from no-load to full-load at power factors of 0.85 lagging, 1.0, and 0.85 leading. Include print out of the Matlab plot and code with your homework. (d) Use Matlab to plot the voltage regulation of this transformer as a function of load current for currents from no-load to full-load at power factors of 0.85 lagging, 1.0, and 0.85 leading. Include a copy of Matlab plot and code with your homework.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 12:10
On a average work day more than work place firs are reorted
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
You know the right answer?
A Y-connected bank of three identical 100-kVA 9000/300-V2 transformers is supplied with power direct...
Questions
question
Business, 23.06.2019 04:00
question
Mathematics, 23.06.2019 04:00
Questions on the website: 13722361