subject
Engineering, 10.03.2020 08:57 kawaunmartinjr10

Write me some pseudocode for one pass of the Selection Sort algorithm through random values stored in an Unordered-List, or Linked-List, of values (rather than a standard "Python" List).
• How would you implement a swap using a Linked-List?
• What is the minimum number of variables required?

Step me through an illustrated example (including all needed variables/arrows) of a Linked-List of size 5, where the positions of nodes 3 and 4 are swapped. Show the pseudocode to accomplish this in your report.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
question
Engineering, 04.07.2019 18:20
For each of the following process: a) sketch the p-v diagram, b)sketch t-s diagram, c) sketch t-v diagram, d) sketch the boundary work on one of the diagrams (a, b or c) and e) sketch the reversible heat transfer on one of the diagrams (a, b or c): 1- isobaric process from compressed liquid to superheated vapor 2- isothermal process from compressed liquid to superheated vapor 3- isentropic process from compressed liquid to superheated vapor
Answers: 3
question
Engineering, 04.07.2019 19:10
Arigid tank contains 10 kg of air at 137 kpa (abs) and 21°c. more air is added to the tank until the pressure and temperature rise to 242 kpa (abs) and 32°c, respectively. determine the amount of air added to the tank. [r-0.287 kj/kg k]
Answers: 3
You know the right answer?
Write me some pseudocode for one pass of the Selection Sort algorithm through random values stored i...
Questions
question
Biology, 23.06.2019 15:20
question
History, 23.06.2019 15:20
question
Mathematics, 23.06.2019 15:20
Questions on the website: 13722363