subject
Engineering, 13.03.2020 03:05 P4thing

A temperature transducer is used to measure the temperature of steam coming out of a steam generator. The following data are available from the manufacturer of the temperature transducer: Range: 0 − 1000 K Sensitivity: ±0.5% of full scale Linearity: ±1.5% of full scale Accuracy: ±1.0% of full scale To determine the repeatability of the transducer, 10 auxiliary tests at the desired average temperature of 800 K were run. The standard deviation of these measurements is 25 K. In a separate test of the data transmission system, 10 tests of the same temperature input resulted in a standard deviation of 20 K. The A/D converter is tested 10 times resulting a standard deviation of 15 K. (a) (10) Calculate the random uncertainty of the temperature measurement at 95% confidence level. (b) (8) Calculate the systematic uncertainty of the temperature measurement. (c) (7) Calculate the total uncertainty of the temperature measurement. If the steam temperature needs to controlled within ±10% from the desired 800 K. Please comment on the adequacy of this device.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
A temperature transducer is used to measure the temperature of steam coming out of a steam generator...
Questions
question
Mathematics, 11.09.2020 23:01
question
Arts, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Mathematics, 11.09.2020 23:01
question
Health, 12.09.2020 01:01
question
Mathematics, 12.09.2020 01:01
question
Mathematics, 12.09.2020 01:01
question
Mathematics, 12.09.2020 01:01
question
English, 12.09.2020 01:01
question
English, 12.09.2020 01:01
question
History, 12.09.2020 01:01
question
Social Studies, 12.09.2020 01:01
question
History, 12.09.2020 01:01
question
Mathematics, 12.09.2020 01:01
Questions on the website: 13722362