subject
Engineering, 13.03.2020 04:55 kaylarenee05080

A distillation column with a total condenser and a partial reboiler is separating two feeds. The first feed is a saturated liquid, and its rate is 100.0 kmol/h. This feed is 55.0 mol% methanol, 21.0 mol% ethanol, 23.0 mol% propanol, and 1.0 mol% butanol. The second feed is a saturated liquid with a flow rate of 150.0 kmol/h. This feed is 1.0 mol% methanol, 3.0 mol% ethanol, 26.0 mol% propanol, and 70.0 mol% butanol. We want to recover 99.3% of the propanol in distillate and 99.5% of the butanol in bottoms. Make appropriate assumptions, and find distillate and bottoms flow rates and mole fractions of distillate and bottoms.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
question
Engineering, 04.07.2019 18:10
During a steady flow process, the change of energy with respect to time is zero. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
You know the right answer?
A distillation column with a total condenser and a partial reboiler is separating two feeds. The fir...
Questions
question
Mathematics, 09.06.2020 23:57
question
Mathematics, 09.06.2020 23:57
Questions on the website: 13722360