subject
Engineering, 16.03.2020 17:28 Izzyfizzy1

A large retirement village has a total retail employment of 120. All 1600 of the households in this village consist of two nonworking family members with household income of $20,000. Assuming that shopping and social/recreational trip rates both peak during the same hour (for exposition purposes). Predict the total number of peak-hour trips generated by this village using the trip generation models.

Consider the retirement village described in above qustion. Determine the amount of additional retail employment (in the village) necessary to reduce the total predicted number of peak-hour shopping trips to 200.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A large retirement village has a total retail employment of 120. All 1600 of the households in this...
Questions
question
Mathematics, 23.09.2019 13:00
question
Mathematics, 23.09.2019 13:00
question
Mathematics, 23.09.2019 13:00
question
Mathematics, 23.09.2019 13:00
Questions on the website: 13722362