subject
Engineering, 27.03.2020 01:01 sandyykn6031

Moist air at 27°C, 1 atm, and 50% relative humidity enters an evaporative cooling unit operating at steady state consisting of a heating section followed by a soaked pad evaporative cooler operating adiabatically. The air passing through the heating section is heated to 45°C. Next, air passing through a soaked pad exiting with 50% relative humidity. Using data from psychrometric chart. Determine

a. The humidity ratio of the entering moist air mixture, in kg(vapor) per kg(dry air).
b. The rate of heat transfer to the moist air passing through the heating section, in kj per kg of mixture.
c. The humidity ratio and temperature, in deg C at the exit of the evaporative cooling section.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
question
Engineering, 06.07.2019 02:30
On solidification from a melt, the polymer polyethylene forms a semi-crystalline spherulite structure. (i) sketch an individual spherulite and label the amorphous and crystalline regions. (ii) draw a schematic to show the changes in specific volume with temperature during cooling from the melt, comparing it to the theoretical extremes of fully crystalline and fully amorphous (indicate tm and tg)
Answers: 2
question
Engineering, 06.07.2019 03:20
Acountershaft is supported by two tapered roller bearings using indirect mounting. the radial bearing loads are 1120 lb for the left-hand bearing and 2190 lb for the right-hand bearing. the shaft rotates at 400 rpm and is to have an l10 life of 40,000 hours and an application factor of 1.4. assume ka2k 15, and find the required radial rating of each bearing
Answers: 3
question
Engineering, 06.07.2019 04:10
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
You know the right answer?
Moist air at 27°C, 1 atm, and 50% relative humidity enters an evaporative cooling unit operating at...
Questions
question
Mathematics, 02.09.2019 13:50
question
Mathematics, 02.09.2019 13:50
Questions on the website: 13722362