subject
Engineering, 31.03.2020 01:36 talia43

The heat required to raise the temperature of m (kg) of a liquid from T1 to T2 at constant pressure is Z T2CpT dT (1) In high school and in first-year college physics courses, the formula is usually given asQ ΔH m Q mCp ΔT mCpT2 ␣T1 (2)T1(a) What assumption about Cp is required to go from Equation 1 to Equation 2? (b) The heat capacity (Cp) of liquid n-hexane is measured in a bomb calorimeter. A small reaction flask (the bomb) is placed in a well-insulated vessel containing 2.00L of liquid n–C6H14 at T 300 K. A combustion reaction known to release 16.73 kJ of heat takes place in the bomb, and the subsequent temperature rise of the system contents is measured and found to be 3.10 K. In a separate experiment, it is found that 6.14kJ of heat is required to raise the temperature of everything in the system except the hexane by 3.10 K. Use these data to estimate Cp[kJ/(mol K)] for liquid n-hexane at T 300 K, assuming that the condition required for the validity ofEquation 2 is satisfied. Compare your result with a tabulated value.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 18:10
Machinery that is a key part of the process and without which the plant or process cannot function is classifed as: (clo4) a)-critical machinery b)-essential machinery c)-general purpose machinery d)-none of the specified options.
Answers: 1
question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
You know the right answer?
The heat required to raise the temperature of m (kg) of a liquid from T1 to T2 at constant pressure...
Questions
Questions on the website: 13722359