subject
Engineering, 03.04.2020 20:22 KaseyT

A two pole, 850 kVA, 2400 Vrms, 60 Hz, three-phase synchronous machine acting as a generator has a syn-chronous reactance of 7.5 a and you can assume the armature resistance to be negligible. It operates at the rated open circuit voltage with a field current of 175 A. Analytically find: (a) 10pts. The magnitude of the field-to-armature mutual inductance. (b) 10pts. The internal voltage value for a load of 750 kW at unity power factor. (c) 10pts. Using a MATLAB script m-file (not a Simscape simulation) create a plot for the constant load power in (b) while varying the field current to archive a maximum and minimum values of 850 kVA leading/lagging. Find the value of the field current that produces the minimum terminal current value. Rel. Date: 3/22/20 Michigan Technological University 2 of 3

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
Journeyman training is usually related (clo2) a)-to specific tasks b)-to cost analysis of maintenance task c)-to control process to ensure quality d)-to installation of machinery
Answers: 2
You know the right answer?
A two pole, 850 kVA, 2400 Vrms, 60 Hz, three-phase synchronous machine acting as a generator has a s...
Questions
question
Mathematics, 08.11.2021 09:20
question
English, 08.11.2021 09:20
question
Mathematics, 08.11.2021 09:20
question
Mathematics, 08.11.2021 09:20
question
Mathematics, 08.11.2021 09:20
question
Mathematics, 08.11.2021 09:20
Questions on the website: 13722367