Engineering, 07.04.2020 19:34 curtez11

Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), where m is the number of horizontal addresses and n is the number of ver>cal addresses. Assume m = 80, n = 12, and that the S/R requires 0.35 min to perform a P/D opera>on, travels horizontally at an average speed of 350 fpm, and travels ver>cally at an average speed of 60 fpm.

Suppose that 40% of storage and retrieval opera>ons are performed as single command and the remaining are performed as dual command. Assume that there are 120 storages per hr and 120 retrievals per hr and that there are 8 S/R machines that are loaded uniformly.

(i) What is the percent utulization of the S/R machines?

(ii) What is the average cycle time per operation (storage/retrieval)?

(iii) What is the maximum throughput (operations per hour) of this AS/R system?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
You know the right answer?
Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), w...
Questions
question
History, 20.10.2019 18:20
question
English, 20.10.2019 18:20
question
Mathematics, 20.10.2019 18:30
Questions on the website: 13722363