A generator bus (slack bus) supplies a 100 MW, 50 Mvar load through a transmission line that can be modeled with a lossless short transmission line model with per unit impedance (100 MVA base) of j0.12. Also assume there is also a 100 Mvar capacitor (measured at 1.0 pu voltage) at the load bus. a. Determine the bus admittance matrix (Y_bus) for the system. b. Calculate the voltage magnitude and angle at the load bus using the Newton-Rapson method. Use the flat-start. Provide the values after 2 iterations. The general power balance equations are given below. P_i = sigma^n _k = 1 |V_i||V_k|(G_ik cos theta_ik + B_ik sin theta_ik) = P_Gi - P_Di Q_i = sigma^n _k = 1 |V_i||V_k| (G_ik sin theta_ik - B_ik cos theta_ik) = Q_Gi - Q_Di

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 16:10
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
question
Engineering, 04.07.2019 18:10
What difference(s) did you notice using a pneumatic circuit over hydraulic circuit.explain why the pneumatic piston stumbles when it hits an obstacle.
Answers: 2
question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet