subject
Engineering, 14.04.2020 22:19 dianamunoz580

A bothersome feature of many physical measurements is the presence of a background signal (commonly called "noise"). In Part 2.2.4 of the experiment, some light that reflects off the apparatus or from neighboring stations strikes the photometer even when the direct beam is blocked. In addition, due to electronic drifts, the photometer does not generally read 0.0 mV even in a dark room. It is necessary, therefore, to subtract off this background level from the data to obtain a valid measurement. Suppose the measured background level is 5.1 mV. A signal of 20.7 mV is measured at a distance of 29 mm and 15.8 mV is measured at 32.5 mm. Correct the data for background and normalize the data to the maximum value. What is the normalized corrected value at 32.5 mm?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:10
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i.d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A bothersome feature of many physical measurements is the presence of a background signal (commonly...
Questions
question
Mathematics, 05.08.2019 09:10
question
Mathematics, 05.08.2019 09:10
question
Mathematics, 05.08.2019 09:10
Questions on the website: 13722367