subject
Engineering, 16.04.2020 02:53 ijohnn15

The semiconductor is a homogeneous, p-type material in thermal equilibrium for t ≤ 0. The excess minority carrier lifetime is 10^-6 ns. At t = 0, an external source is turned on which produces excess carriers uniformly at rate of g'=1020 cm^-3s^-1. At t = 2*10^-6 s , the external source is turned off.

(a) Derive the expression for the excess-electron concentration as a function of time for 0 ≤ t ≤[infinity].

(b) Determine the value of excess electron concentration at (i) t = 0, (ii) t = 2*10^-6 s , (iii) t = 3*10^-6 s and (iv) t = [infinity].

(c) Plot the excess electron concentration as a function of time.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
You know the right answer?
The semiconductor is a homogeneous, p-type material in thermal equilibrium for t ≤ 0. The excess min...
Questions
question
Geography, 23.10.2020 03:01
question
World Languages, 23.10.2020 03:01
question
Mathematics, 23.10.2020 03:01
question
Mathematics, 23.10.2020 03:01
question
Mathematics, 23.10.2020 03:01
question
Mathematics, 23.10.2020 03:01
Questions on the website: 13722367