A building has the following dimensions and characteristics: footprint of 100 ft x 50 ft and 8 stories, 10 feet floor-to-floor height for each floor. The window-wall ratio is 33 Walls have an overall R-value of 20, windows have a U-value of 0.6. The roof has an R value of 30. Building is programmed as all office with 150 square feet per person

Part a

Calculate the design heating load, Q. in BTUH, assuming heating design conditions of 74 degree F inside and 10 degree Foutside and 15 CFM ventilation air per occupant.

Part b

Calculate the annual estimated fuel use in therms, assuming 3,800 degree-days (NYC), 80% efficient boiler, using natural gas at 100,000 BTU/Therm

Q windows annual =
Q wall annual =
Q roof annual
Q infiltration annual =

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 04.07.2019 18:10
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
You know the right answer?
A building has the following dimensions and characteristics: footprint of 100 ft x 50 ft and 8 stori...
Questions
question
Mathematics, 24.10.2020 05:50
question
Mathematics, 24.10.2020 05:50
question
English, 24.10.2020 05:50
question
Mathematics, 24.10.2020 05:50
question
Mathematics, 24.10.2020 05:50
question
Mathematics, 24.10.2020 05:50
question
Mathematics, 24.10.2020 05:50
Questions on the website: 13722360