A 230 V, single-phase supply feeds the following loads: (a) incandescent lamps taking a current

of 6 A at unity power factor; (b) fluorescent lamps taking a current of 5 A at 0.75 leading power

factor; (c) a motor taking a current of 7 A at 0.7 lagging power factor. You are required to

correct the power factor to unity.

a) Show how it can be achieved by connecting a parallel reactance to the load

- provide the phasor diagram based on computed branch currents; and the power

triangles before and after power factor correction.

- provide the appropriate kVar rating of reactance, and if it’s a capacitor bank compute

the capacitance or if it’s an reactor (inductor) compute the inductance.

b) If it is proposed to use series reactance to perform power factor correction, show how this

can be achieved and comment on this approach.

d) Verify your answers using Matlab/Simulink

- show the rms currents on the Simulink model

- Plot the instantaneous branch currents and show clearly how the phase angle between

the supply voltage and supply current changes, accordingly

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A 230 V, single-phase supply feeds the following loads: (a) incandescent lamps taking a current
Questions
question
History, 11.02.2020 20:58
question
History, 11.02.2020 20:58
question
Mathematics, 11.02.2020 20:58
question
Mathematics, 11.02.2020 20:58
Questions on the website: 13722367