Consider the adiabatic compressor from a refrigerator that uses refrigerant R-134a as the working fluid, flowing at 0.05 kg/s. The refrigerant enters the compressor as a saturated vapor at a pressure of 0.14 MPa. The pressure of the refrigerant at the exit of the compressor is 0.8 MPa. Please interpolate for this problem where needed.

a. If the compressor is isentropic, what is the exit temperature?
b. What is the minimum amount of power (work) that this compressor might theoretically use?
c. If the isentropic efficiency of the actual, non-ideal, compressor is 0.85, what is the actual amount of power (work) that this compressor requires?
d. What is the entropy generated by this device? Assume that the compressor is adiabatic.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Wiy doeres rere okhn a pump whon working betwon the same pressure range?
Answers: 2
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 06.07.2019 04:10
Aheat pump that operates on the ideal vapor compression cycle with refrigerant-134a is used to heat water from 15°c to 45°c at a rate of 0.12 kg/s. the condenser and evaporator pressures are 1.4 and 0.32 mpa, respectively determine: (a) the power input to the heat pump
Answers: 1
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10°c. the air leaves the coil at 15°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
Consider the adiabatic compressor from a refrigerator that uses refrigerant R-134a as the working fl...
Questions
question
History, 06.12.2021 07:50
question
Mathematics, 06.12.2021 07:50
question
Mathematics, 06.12.2021 07:50
question
Mathematics, 06.12.2021 07:50
question
Mathematics, 06.12.2021 07:50
question
Mathematics, 06.12.2021 07:50
Questions on the website: 13722360