subject
Engineering, 21.04.2020 16:22 Nelly6978

Define a function UpdateTimeWindow() with parameters timeStart, timeEnd, and offsetAmount. Each parameter is of type int. The function adds offsetAmount to each of the first two parameters. Make the first two parameters pass by pointer. Sample output for the given program:

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 06.07.2019 03:10
Asolid steel sphere (k=63.9 w m-1 k-1 , ? =7832 kg m-3 , c=0.523 kj kg-1 k-1 ), 100 mm in diameter is initially at a uniform temperature of 500o c and is suddenly quenched in a large oil bath for which t? = 100o c and h = 3200 w m-2 k-1. estimate the time required for the sphere to cool to 200o c and to 110o c
Answers: 1
question
Engineering, 06.07.2019 04:10
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
You know the right answer?
Define a function UpdateTimeWindow() with parameters timeStart, timeEnd, and offsetAmount. Each para...
Questions
question
Mathematics, 01.06.2021 07:00
question
English, 01.06.2021 07:00
question
History, 01.06.2021 07:00
question
Mathematics, 01.06.2021 07:10
question
Mathematics, 01.06.2021 07:10
Questions on the website: 13722360