subject
Engineering, 21.04.2020 20:22 Govind4954

Design a Mealy machine for a 20 cent candy dispensing machine which accepts nickel (n) , dime (d) and quarter(q) . It gives candy as well change in the form of nickels only. To help you, here are the some of the elements of the machine: States: 0, 5, 10 and 15 represent the amount of money already inserted in the machine. n, d and q representing coins inserted in the machine Output: c0 (candy and no change), c1 (one nickel as change), c2(two nickels as change ), c3 (three nickels as change), and c4 (four nickels as change)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
You know the right answer?
Design a Mealy machine for a 20 cent candy dispensing machine which accepts nickel (n) , dime (d) an...
Questions
question
World Languages, 18.05.2021 19:30
question
Chemistry, 18.05.2021 19:30
question
Mathematics, 18.05.2021 19:30
question
Mathematics, 18.05.2021 19:30
Questions on the website: 13722359