subject
Engineering, 22.04.2020 02:32 lesliesaucy4987

Calculate the modulus of elasticity of carbon-epoxy composite under isostraincondition if thecomposite consists of 40% carbon fibers and 60% epoxy by volume. Also, calculate the percentageof load carried by the carbon fibers. The modulus of elasticity of the carbon fibers and the epoxyare 350 GPa and3.5 GPa, respectively.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:10
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2
question
Engineering, 04.07.2019 19:20
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
question
Engineering, 06.07.2019 04:10
An inventor claims to have developed a reversed heat engine (ie. a heat pump) which is able to deliver 10 kj heat into the room at 20°c from outside ambient temperature of -10°c by consuming only 2 kj electricity in winter. this claim is a)-impossible b)-possible only if the heat pump is ideal c)-practically possible d)-unable to be assessed as it depends on the working fluid used in the heat pump.
Answers: 2
You know the right answer?
Calculate the modulus of elasticity of carbon-epoxy composite under isostraincondition if thecomposi...
Questions
Questions on the website: 13722367